DIFFER
DIFFER Publication

Video analysis of dust events in full-tungsten ASDEX Upgrade

Author
Abstract

Fast video data recorded during seven consecutive operation campaigns (2008–2012) in full-tungsten ASDEX Upgrade have been analyzed with an algorithm developed to automatically detect and track dust particles. A total of 2425 discharges have been analyzed, corresponding to 12 204 s of plasma operation. The analysis aimed at precisely identifying and sorting the discharge conditions responsible of the dust generation or remobilization. Dust rates are found to be significantly lower than in tokamaks with carbon PFCs. Significant dust events occur mostly during off-normal plasma phases such as disruptions and particularly those preceded by vertical displacement events (VDEs). Dust rates are also increased but to a lower extent during type-I ELMy H-modes. The influences of disruption energy, heating scenario, vessel venting and vessel vibrations are also presented.

Year of Publication
2017
Journal
Nuclear Fusion
Volume
57
Issue
3
Number of Pages
036002
DOI
10.1088/1741-4326/aa4e56
PId
ed5d85b4fd4c48439d8c98212f5b8c3a
Alternate Journal
Nucl. Fusion
Journal Article