The ECW installation at the TEXTOR tokamak

TitleThe ECW installation at the TEXTOR tokamak
Publication TypeJournal Article
Year of Publication2003
AuthorsJ.W Oosterbeek, W.A Bongers, A.F van der Grift, J.A Hoekzema, O.G Kruijt, A.J Poelman, P.R Prins, J. Scholten, F.C Schüller, C.J Tito, E. Westerhof
JournalFusion Engineering and Design
Volume66-8
Pagination515-519
Date PublishedSep
Type of ArticleArticle
ISBN Number0920-3796
Accession NumberISI:000185617900075
Keywordscontrol, gyrotron, TEXTOR
Abstract

Previous electron cyclotron wave experiments on TEXTOR were performed using a 110 GHz, 350 kW, 200 ms gyrotron. The installation is presently extended with a new gyrotron at 140 GHz, which produces more than 800 kW of RF power in a Gaussian beam for more than 3 s at 1% duty cycle. Auxiliary systems have been overhauled and upgraded. The installation can be conveniently switched between gyrotrons while the control system is kept extremely versatile allowing to switch between manual expert operation and fully automated operation from the TEXTOR control room. A scheme is being developed to allow control of the steerable launcher depending on real-time plasma parameters. (C) 2003 Elsevier Science B.V. All rights reserved.

URL<Go to ISI>://000185617900075
Division

Fusion Physics

Department

Tokamak physics

PID

2615211f21eebc18fec60c8294621a22

Alternate TitleFusion Eng. Des.