Demonstration of low-loss electron beam transport and mm-wave experiments of the fusion-FEM
Label | Value |
---|---|
Author | |
Abstract |
In the Fusion-FEM electrostatic Free Electron Maser, an electron beam loss current of less than 0.2% is essential for long-pulse operation. At reduced beam current, 3 A instead of the nominal 12 A, we have demonstrated electron beam acceleration and transport through the undulator at current losses less than 0.02%. This paper summarizes the results of beam transport experiments and outlines the simple yet effective beam diagnostics system. The status of the mm-wave cavity and low-power measurements are given. It is shown that cavity characteristics, such as losses, bandwidth, frequency-tuning and feedback coefficient, can be checked in situ via the output window, by injecting a low power test-signal into the mm-wave system and analyzing the reflected signal. (C) 1998 Elsevier Science B.V. All rights reserved. |
Year of Publication |
1998
|
Journal |
Nuclear Instruments & Methods in Physics Research Section a-Accelerators Spectrometers Detectors and Associated Equipment
|
Volume |
407
|
Number |
1-3
|
Number of Pages |
327-331
|
Date Published |
Apr 21
|
ISBN Number |
0168-9002
|
DOI | |
PId |
573debe9387d7795ee9d5d8039e0c4b5
|
Journal Article
|
|