Collective Thomson scattering measurements with high frequency resolution at TEXTOR

TitleCollective Thomson scattering measurements with high frequency resolution at TEXTOR
Publication TypeJournal Article
Year of Publication2010
AuthorsM. Stejner, S.K. Nielsen, S.B Korsholm, M. Salewski, H. Bindslev, V. Furtula, F. Leipold, F. Meo, P.K Michelsen, D. Moseev, A. Burger, M. Kantor, M. de Baar
JournalReview of Scientific Instruments
Volume81
Number10
Pagination5
Date PublishedOct
Type of ArticleProceedings Paper
ISBN Number0034-6748
Accession NumberISI:000283754000053
Abstract

We discuss the development and first results of a receiver system for the collective Thomson scattering (CTS) diagnostic at TEXTOR with frequency resolution in the megahertz range or better. The improved frequency resolution expands the diagnostic range and utility of CTS measurements in general and is a prerequisite for measurements of ion Bernstein wave signatures in CTS spectra. The first results from the new acquisition system are shown to be consistent with theory and with simultaneous measurements by the standard receiver system. [doi:10.1063/1.3475540]

URL<Go to ISI>://000283754000053
Division

Fusion Physics

PID

26becb39e71a791e3b9397109f7fbc6e