DIFFER
DIFFER Publication

Carbon charge exchange analysis in the ITER-like wall environment

Author
Abstract

Charge exchange spectroscopy has long been a key diagnostic tool for fusion plasmas and is well developed in devices with Carbon Plasma-Facing Components. Operation with the ITER-like wall at JET has resulted in changes to the spectrum in the region of the Carbon charge exchange line at 529.06 nm and demonstrates the need to revise the core charge exchange analysis for this line. An investigation has been made of this spectral region in different plasma conditions and the revised description of the spectral lines to be included in the analysis is presented.

Year of Publication
2014
Journal
Review of Scientific Instruments
Volume
85
Issue
11
Number of Pages
11E412
DOI
10.1063/1.4890118
PId
348b376ac3c6925486f41346225b2c4d
Alternate Journal
Rev. Sci. Instrum.
Journal Article
Download citation