Cross-section analysis of the Magnum-PSI plasma beam using a 2D multi-probe system
Label | Value |
---|---|
Author | |
Abstract |
The linear plasma generator Magnum-PSI was designed for the study of plasma-surface interactions under relevant conditions of fusion devices. A key factor for such studies is the knowledge of a set of parameters that characterize the plasma interacting with the solid surface. This paper reports on the electrical diagnosis of the plasma beam in Magnum-PSI using a multi-probe system consisting of 64 probes arranged in a 2D square matrix. Cross-section distributions of floating potential and ion current intensity were registered for a hydrogen plasma beam under various discharge currents (80-175 A) and magnetic field strengths (0.47-1.41 T in the middle of the coils). Probe measurements revealed a high level of flexibility of plasma beam parameters with respect to the operating conditions. |
Year of Publication |
2015
|
Journal |
Plasma Sources Science and Technology
|
Volume |
24
|
Number |
1
|
Issue |
1
|
Number of Pages |
015014
|
DOI | |
PId |
8a55d702d92adf599ac1844a32d79819
|
Alternate Journal |
Plasma Sources Sci. Technol.
|
Journal Article
|
|
Download citation |