DIFFER
DIFFER Publication

Cross-section analysis of the Magnum-PSI plasma beam using a 2D multi-probe system

Label Value
Author
Abstract

The linear plasma generator Magnum-PSI was designed for the study of plasma-surface interactions under relevant conditions of fusion devices. A key factor for such studies is the knowledge of a set of parameters that characterize the plasma interacting with the solid surface. This paper reports on the electrical diagnosis of the plasma beam in Magnum-PSI using a multi-probe system consisting of 64 probes arranged in a 2D square matrix. Cross-section distributions of floating potential and ion current intensity were registered for a hydrogen plasma beam under various discharge currents (80-175 A) and magnetic field strengths (0.47-1.41 T in the middle of the coils). Probe measurements revealed a high level of flexibility of plasma beam parameters with respect to the operating conditions.

Year of Publication
2015
Journal
Plasma Sources Science and Technology
Volume
24
Number
1
Issue
1
Number of Pages
015014
DOI
PId
8a55d702d92adf599ac1844a32d79819
Alternate Journal
Plasma Sources Sci. Technol.
Journal Article
Download citation
Citation
Costin, C., Anita, V., Ghiorghiu, F., Popa, G., De Temmerman, G., van den Berg, M. A., … Brons, S. (2015). Cross-section analysis of the Magnum-PSI plasma beam using a 2D multi-probe system. Plasma Sources Science and Technology, 24(1), 015014. https://doi.org/10.1088/0963-0252/24/1/015014