DIFFER
DIFFER Publication

Loading of deuterium and helium by Pilot-PSI plasma and their detection by in-situ LIBS

Author
Abstract

Laser-induced breakdown spectroscopy (LIBS) is a promising method for quantifying the fuel content of the plasma-facing components of ITER both in between plasma discharges (in-situ) and after maintenance operations. The aim of the present study is to test the applicability of in-situ LIBS for monitoring deuterium (D) and helium (He) content of W samples exposed to fusion relevant plasma fluxes in the linear plasma device Pilot-PSI.
The D loading was performed during 1000 s of plasma exposure at low (200-300 °C) surface temperatures. Despite of low intensity and noisy LIBS spectra, H and D lines, at 656.1 and 656.3 nm, respectively, could be fitted with Lorentzian contours and reliably resolved at 1.2 mbar background pressure of argon.
In the case of He loading, the samples were also exposed to plasma during 1000 s while the surface temperature reached values up to 720 °C at the center. Already at 10–2 mbar residual pressure of the device, the He I line at 587.6 nm was visible for the first 2–3 laser shots.
We demonstrated that in-situ LIBS is a reliable method for detection of He and D retention in ITER-relevant materials. Nevertheless, for measuring relative and absolute concentrations of D and He in the ITER-relevant samples, further studies are needed.

Year of Publication
2017
Journal
Nuclear Materials and Energy
Volume
12
Number of Pages
694-698
Date Published
08/2017