DIFFER
DIFFER Publication
Label | Value |
---|---|
Author | |
Abstract |
Divertor tile calorimetry is shown to provide accurate routine energy balance in JET, By shifting the plasma from pulse-to-pulse a power profile is reconstructed which shows a narrow high power peak at the outer target, 2 mm midplane in width. This feature carries half the total divertor power in a typical type I ELMy PI-mode and is the dominant factor determining the in/out divertor energy asymmetry, (C) 2001 JET Joint Undertaking. Published by Elsevier Science B.V. All rights reserved. |
Year of Publication |
2001
|
Journal |
Journal of Nuclear Materials
|
Volume |
290
|
Number of Pages |
668-672
|
Date Published |
Mar
|
ISBN Number |
0022-3115
|
DOI | |
PId |
f8411f55e86c2f46c3b392184f1da2b2
|